SWIMMING POOL PARTS

POOL FILTER

  • 1. Filter :- Swimming Pool Sand Filter Normal position during operation of system
  • 2. Backwash :- Position when operation system to purge filter of accumulated debris. This normally is necessary when filter pressure gauge read 10 PSI higher than starting pressure on s clear filter.
  • 3. Rinse :- This position only used with sand filters and is designed to flush stray sand from system before returning to filter operation after back washing. 4. Closed :- Valve may be set in closed position when servicing filter tanks located below water level.
  • 5. Re-Circulate :- This position permits pump to continue recirculation water (chemicals, heat, etc.) without flow through filter. this is advantageous when filter or its components are being repaired or replaced. 6.Waste :- This position permits draining or lowering of pool position, quickly move handle to another position to avoid air getting into pipe. 7.Winterizing :- This position is used to prevent from freezing. 8.Service :- The screw on the handle should be replaced while repairing.
  • 9. Suitable with 1.0 hp Pump. Note :- Sand media is not included

INLETS

Product Specification

Usage/ApplicationSwimming Pool
ShapeRound
Number Of Holes1
MaterialABS
ColorWhite
Diameter40-50 mm
Flow Rate6000-6500 liter/Hr
BrandMagline Pools
 

Product Description

Eye Ball Nozzle inlets made in white abs, with multiple flow UV protected appreciated for long life. Connection 50mm/63mm

FILTRATION PUMP

For water circulation in swimming pool filtration system.

For clean and slight dirty water with solids in suspension.

The pump should be installed in an enclosed environment or sheltered from inclement weather.

Female threaded inlet/outlet available on request for SWIM series.

230V/60HZ, 110V/60HZ, 110V/50HZ are available on request for SWIM series.

Self priming 2-3m.

Handle available on request.

 

FS SERIES FILTER SYSTEM

The systems are designed for quick assembly and precise alignment of components

Both fiber glass filter and Plastic filter are available

6-position multiport valve : filter, backwash, rinse, waste, recirculation, closed

All models are one carton design

heat pump is a device that can heat a building (or part of a building) by transferring thermal energy from the outside using the refrigeration cycle. Many heat pumps can also operate in the opposite direction, cooling the building by removing heat from the enclosed space and rejecting it outside. Units that only provide cooling are called air conditioners.

When in heating mode, a refrigerant at outside temperature is being compressed. As a result, the refrigerant becomes hot. This thermal energy can be transferred to an indoor unit. After being moved outdoors again, the refrigerant is decompressed — evaporated. It has lost some of its thermal energy and returns colder than the environment. It can now take up the surrounding energy from the air or from the ground before the process repeats. Compressors, fans, and pumps run with electric energy.

Common types are air source heat pumpsground source heat pumps, water source heat pumps and exhaust air heat pumps. They are also used in district heating systems.

error: Ask to ULTRA-Z !!